Model Number: ZKJ-A2KW
Brand Name: ZONHAN
Key Specifications/Special Features:
ZKJ–A model product characteristics:◆ The product can be manufactured in accordance with either JB/T6939.1-2004 industrial standard, GB/T 19115.1-2003 national standard or users’ technical requirements.◆ ZKJ-A controllers adopt multiple-line three-phase load discharging control.◆ The total power of three-phase load discharging is 220% larger than the rated power of the wind turbine generator. The three-phase load discharging power of the first line is 80-100% of the rated power of the wind turbine generator; in case of exceeding the scope of the first line load discharging power, the three-phase load discharging of the second line will automatically start to ensure safe operation of the overall wind turbine generation system.◆ Under the circumstances of decoupling and damage of the battery, the three-phase load discharging will automatically start to avoid the idle run of the wind turbine generator and the occurrence of runaway accident.◆ It has reverse connection, anti-decoupling and damage-resisting protection of the battery.◆ Over-charging protection of the battery: When the battery is full (the battery pressure reaching 125% of the rated pressure), the controller will automatically carry out three-phase load discharging to stop charging the battery.◆ Auto recovery of battery charging: When the battery pressure reduces to 108% of the rated pressure, the load discharger will stop three-phase load discharging to automatically recover battery charging.◆ According to the category of the wind turbine generator, the controller can be additionally equipped with mechanical yawing, swing-tai, mechanical or hydraulic, pneumatic, magnetic and other brake functions.◆ LED status indication: Clearly present the working status of the wind turbine generator, solar panel, battery and controller.
◆ Ammeter and voltmeter indication: Indicate the charging current and voltage of the battery.
◆ The controller is equipped with manual three-phase load discharging switch; the user may use it according to actual circumstances. When using this switch, the wind turbine generator will forcibly carry out three-phase load discharging.
Technical parameters of the ZKJ-A1 off - grid wind turbine controller |
Type |
1KW-24V |
2KW-48V |
3KW-48V |
Battery |
24Vdc |
48Vdc |
48Vdc |
Function |
Charge, control |
Operating environment |
Temperature -35-40℃, humidity≤80% |
3-phase load voltage of the wind turbine |
29±1Vdc |
58±1Vdc |
58±1Vdc |
Recovery charging voltage of the wind turbine |
26±1Vdc |
54±1Vdc |
54±1Vdc |
Low-voltage of the battery |
20±1Vdc |
40±1Vdc |
40±1Vdc |
Self-provided connecting wire of the battery |
>10 mm |
>10 mm |
>12 mm |
Fuse |
63A |
63A |
100A |
Size |
510*360*230 mm |
470*350*320 mm |
445*435*380 |
Weight |
9Kg |
11.8Kg |
17Kg |